tubelar back wash filter
Internal backwash utilizes the system’s filtrate to clean the system. This is accomplished by changing the lower valve from the inlet to the drain position on one filter unit. A portion of the filtrate from the remaining on-stream units flows in the reverse direction through the backwashing unit to dislodge collected solids. Each unit is backwashed in turn, individually and consecutively to return the system to a clean condition. Internal backwash should be considered when the process stream is of sufficient flow and pressure to ensure an adequate backwash, or when the process stream is
Solids removal from 1 to 1,700 microns • Single system flow rates up to 3,000 gpm (681 m3 /hr) • Smooth pipe and nozzle connection transitions to avoid dead spots in the fluid stream and minimize pressure drop • Broad selection of filter media materials and retentions suitable for a wide range of applications • Proprietary 3-way, full-ported valves allow fast, frequent sequencing and maximum cleaning force during backwashing • Isolated top-to-bottom backwash flow ensures complete and efficient media cleaning while continuing to deliver filtered product downstream • Numerous automated backwash options for operator-free service and minimal backwash effluent (<2% of system volume)